Brackish Water Desalination Through Eolic Reverse Osmosis for Rural Communities

Author(s): Belzahet Treviño Arjona, Ana Hilda Santillan, José Rodríguez
Dr. Belzahet Treviño Arjona, M.S. Ana Hilda Santillan and M.S. José Rodríguez Puerto Galera # 455, Col. Las Brisas, Monterrey, Nuevo León, México, C.P. 64780 Tel: 528-180-29-47-67, FAX: 528-181-03-00-56, Email: btrevino@ianl.org.mx

Keyword(s): Desalination, Eolic Energy, Reverse Osmosis

Article: abs116_article.pdf
Poster: abs116_poster.pdf
Get Adobe Reader

Session: Poster session 4
AbstractMany rural areas located in arid or semi arid climates depend on underground

water as the only source of fresh water. Unfortunately, many of these sources present high levels of toxic and non-

toxic elements like sodium chloride, sodium sulfate, arsenic and fluoride. These elements like many others make

underground water unacceptable for human consumption, based on the concentrations found and on the local

potable water standards. Reverse osmosis (RO) has become the standard way to desalinate small scale process.

RO investment costs have been reduced in the last 20 years to an affordable amount even for rural areas; however

operating costs have increased again in the past 20 years due to an increase in the rising cost of energy. In many

cases rural areas have a very low income and energy sources are sometimes not available, this can lead to

abandoned RO rural units or even result in no units at all. The abandonment of rural RO units is the direct result of

the absence of both electrical and diesel payments. This situation brought the objective to develop an eolic RO unit

with a lower operating cost, compared to the standard electrical RO unit operating cost. The objectives of the

project were 1) To develop of an eolic energy buffer system to reduce pressure variation between the commercial

eolic pump (wind mill) and the RO membrane unit. 2) The installation and performance monitor of a pilot eolic RO

unit under different wind conditions. 3) The evaluation of energy savings per m3 of produced potable water. A

commercial 16ft wind mill with a 3” piston from Aeromotor along with three 4” x 40” spiral wound membrane model

SE4040CZH from Osmonics were selected and installed at an arsenic and fluoride underground water source with

897 ppm of total dissolved solids (TDS). An eolic energy buffer was designed and installed between the wind mill

and the RO membranes. The eolic energy buffer controlled operating pressure at wind speeds from 0 to 40 km/hr.

The buffer system was able to operate water pressure between 3.75 and 4.5 bar. The minimum wind speed that

obtained the lowest operating pressure (3.75bar) was 10 km/hr with a water production of 45 l/day. The maximum

useful wind speed was 18 km/hr with a maximum operating pressure of 4.5 bar and a maximum water production of

70 l/day. The pilot eolic RO averaged in a 12 month period a wind speed of 8.46 km/hr, and the regulate operating

pressure was an average of 4.12 bar with an average water production of 1000 l/day and 49 ppm of TDS. No

external energy was needed in the desalination process aside from eolic energy. Energy savings from the use of eolic

RO are 2731 Kj/m3. The Eolic Energy Buffer System regulates inlet pressure at set point allowing commercial wind

mills and reverse osmosis membranes to be connected and operate with regular maintenance. The Eolic Reverse

Osmosis system represents a feasible, reliable and sustainable small scale desalination option for rural areas.

  Return up